Skip to main content
. 2022 Jan 19;12(2):112. doi: 10.3390/membranes12020112

Table 2.

Membrane module specifications and operating conditions.

Parameter Value
Membrane Contactor
Membrane material Polypropylene
Fiber inner diameter, di (m) 2.20 × 10−4
Fiber outer diameter, do (m) 3.00 × 10−4
Membrane thickness, δ (m) 0.4 × 10−4
Effective length of the fiber, L (m) 0.1132
Number of fibers, N 7400
Membrane pore diameter, dp (m) 4.00 × 10−8
Effective inner membrane area, Ai (m2) 0.58
Effective outer membrane area, Ao (m2) 0.79
Lumen side volume, Vl (mL) 53
Shell side volume, Vg (mL) 78
Porosity, ε 40
Packing factor, ϕ 0.36
Tortuosity, τ a 6.4
Operating conditions
Operating configuration Countercurrent
Operating temperature T (°C) 25
Liquid flowrate, Ql (mL min−1) 100–400
Liquid velocity, Vl (m s−1) 5.93 × 10−3–2.37 × 10−2
Liquid Reynold number, Rel (-) 1.29–5.19
Gas flowrate, Qg (mL min−1) 50–200
Gas velocity, Vg (m s−1) 1.11 × 10−3–4.43 × 10 −3
Gas Reynold number, Reg (-) 3.70 × 10−2–1.48 × 10−1

a τ =(2ε)2ε [41].