Table 3.
Reference | Effluent | Membrane | Operating Mode | Vl (m s−1) |
Ql (mL min−1) |
Vg (m s−1) |
Qg (mL min−1) |
Degassing Efficiency (%) |
---|---|---|---|---|---|---|---|---|
This Work | Saturated water | PP | Sweep gas | 0.006 | 100 | 0.0020 | 100 | 95.7 |
This Work | Saturated water | PP | Sweep gas | 0.024 | 400 | 0.0020 | 100 | 78.1 |
This Work | Saturated water | PP | Sweep gas | 0.006 | 100 | 0.004 | 200 | 78.1 |
[36] | AnMBR prototype-plant | PDMS | Vacuum | - | 833 | - | - | 45.0 |
[36] | AnMBR prototype-plant | PDMS | Vacuum | - | 3333 | - | - | 18.0 |
[37] | Saturated water | PP | Sweep gas + vacuum | 0.016 | 83 | 0.0004 | 8.3 | 84 |
[37] | Saturated water | PP | Sweep gas + vacuum | 0.089 | 466 | 0.0004 | 8.3 | 42 |
[43] | EGSB | PP | Sweep gas + vacuum | 0.013 | 68 | 0.0220 | 433 | 82 |
[43] | EGSB | PP | Sweep gas + vacuum | 0.086 | 453 | 0.0220 | 433 | 45 |