Published in final edited form as: Magn Reson Med. 2017 Mar 13;79(1):256–263. doi: 10.1002/mrm.26669

Table 1.

Simulation Results: Summary of Peak and Steady-State 17O Water Uptake and Washout Rate in Designed Phantom.

Compartment Peak 17O Signal Steady-State 17O Signal Washout Rate (min−1)
Chosen values
#1 6 4 1.5
#2 5 3.5 0.8
#3 3.5 3 0.4
Noiseless
#1 6 ± 0.02 4 ± 0.01 1.5 ± 0.01
#2 4.99 ± 0.03 3.5 ± 0.01 0.79 ± 0.02
#3 3.45 ± 0.04 2.98 ± 0.01 0.38 ± 0.02
SNR = 20
#1 5.86 ± 0.2 3.97 ± 0.16 1.51 ± 0.13
#2 4.98 ± 0.19 3.47 ± 0.13 0.81 ± 0.06
#3 3.57 ± 0.11 3 ± 0.04 0.42 ± 0.07
SNR = 10
#1 5.86 ± 0.35 3.98 ± 0.3 1.48 ± 0.33
#2 4.94 ± 0.45 3.46 ± 0.36 0.83 ± 0.3
#3 3.59 ± 0.16 2.96 ± 0.18 0.38 ± 0.24

SNR = signal-to-noise ratio.