Table 2.
Diagnostic performance of the metabolite biomarker panel for the classification of patients with laryngeal cancer and healthy individuals.
| Training set | Leave one out cross-validation | |||||
| AUC (95% CI) | Sensitivity | Specificity | AUC (95% CI) | Sensitivity | Specificity | |
| Arg | 0.7533 (0.6449–0.8617) | 0.6923 | 0.7925 | 0.7291 (0.6224–0.8358) | 0.6923 | 0.7736 |
| Pro | 0.7005 (0.5882–0.8128) | 0.6923 | 0.6792 | 0.6681 (0.5546–0.7817) | 0.6667 | 0.6604 |
| C26 | 0.7467 (0.6463–0.8472) | 0.6154 | 0.8302 | 0.6686 (0.5551–0.7821) | 0.6154 | 0.8302 |
| Orn/Cit | 0.6713 (0.5562–0.7863) | 0.5641 | 0.7925 | 0.6251 (0.5082–0.7419) | 0.5641 | 0.7736 |
| C18:1-OH | 0.7937 (0.7096–0.8777) | 0.6410 | 0.9245 | 0.6207 (0.5036–0.7379) | 0.6410 | 0.9245 |
| Five-biomarker panel | 0.9308 (0.8782–0.9834) | 0.8974 | 0.8868 | 0.8921 (0.8198–0.9644) | 0.8974 | 0.8302 |
Arg = arginine, C18:1-OH = 3-hydroxy-octadecenoylcarnitine, C26 = hexacosanoic carnitine, Cit = citrulline, Orn = ornithine, Pro = proline.