Table 3.

Summary of the reproducibility/repeatability studies.

Reference Intra-repro Inter-repro Repeatability Condition Variables Object Modality
Jha et al. [23], 2021 30.7%
(332/1080)
14.3%
(154/1080)
82.2% (888/1080) ICC >0.90 Slice Sickness Phantoms CT
Emaminejad et al. [24], 2021 8.0%
(18/226)
/ / CCC>0.90 Reconstruction Patients CT
7.5%
(17/226)
/ / CCC>0.90 Radiation Dose Patients CT
Kim et al. [25], 2021 11.0%
(112/1020)
/ / CCC>0.85 Acceleration Factors Patients MRI
Ymashita et al. [26], 2020 / 5.6%
(15/266)
/ CCC>0.90 Different Scanners Patients CECT
Fiset et al. [27], 2019 / 22.6%
(398/1761)
/ ICC >0.90 Different Scanners Patients MRI
Saeedi et al. [28], 2019 20.5%
(8/39)
/ / CoV< 5% Tube Voltage Phantoms CT
30%
(13/39)
/ / CoV< 5% Tube Current Phantoms CT
Meyer et al. [29], 2019 20.8%
(22/106)
/ / R2>0.95 Radiation Dose Patients CT
52.8%
(56/106)
/ / R2>0.95 Reconstruction Patients CT
39.6%
(42/106)
/ / R2>0.95 Reconstruction Patients CT
12.3%
(13/106)
/ / R2>0.95 Slice Sickness Patients CT
Perrin et al. [30], 2018 24.8%
(63/254)
/ / CCC>0.90 Injection Rates Patients CECT
13.4%
(34/254)
/ / CCC>0.90 Resolution Patients CECT
Midya et al. [31], 2018 11.7%
(29/248)
/ / CCC>0.90 Tube Current Phantoms CT
19.8%
(49/248)
/ / CCC>0.90 Noise Phantoms CT
63.3%
(157/248)
/ / CCC>0.90 Reconstruction Patients CT
Altazi et al. [32], 2017 21.5%
(17/79)
/ / Mean difference <25% Reconstruction Patients PET
Zhao et al. [13], 2016 11.2%
(10/89)
/ / CCC>0.90 Reconstruction Patients CT
/ / 69.7%
(62/89)
CCC>0.90 / Patients CT
Hu et al. [33], 2016 / / 64.0%
(496/775)
ICC>0.80 / Patients CT
Choe et al. [34], 2019 15.2%
(107/702)
/ / CCC>0.85 Reconstruction Patients CT

CCC: concordance correlation coefficient; ICC: intraclass correlation coefficient; CoV: coefficient of variation; R2: R-squared; CT: computed tomography; MRI: magnetic resonance imaging; CECT: consecutive contrast-enhanced computed tomography; PET: positron emission tomography.