Figure 2.
Schematic diagram of the test cell and representation of the main ionic transport in DD and IEMB experiments. Effective membrane area, 11.3 cm2. Volume of each compartment, 175 mL. The modifications to operate as an IEMB are represented in grey colour and italic lettering. The receiver compartment under IEMB operation was referred to as biocompartment.
