Table 3. Sensory percept details for participant 2.

Table provides the electrode details, stimulation parameters that evoked a sensory percept in participant 2 and the percept description. All percepts were felt only in the contralateral (left) hand.

Electrode Type Lead/Grid Electrode Pair Threshold Amplitude (mA) Frequency (Hz) Percept Description

SEEG RPs 9–10 0.5 20 Tingling
Digit 4, towards bottom of finger
RPs 10–11 0.5 20 Tingling
Digit 4 fingertip; some sensation in digit 3
RPs 11–12 0.65 20 Tingling, whole of digit 4
RPs 12–13 1 20 Tingling, Digit 3 fingertip
RPi 5–6 4.8 20 Tingling by the thumb
RPi 6–7 2.1 20 Tingling index finger, small spot
HD-ECoG HDG 39–40 1.5 50 Tingling, wrist
HDG 40–41 1.7 50 Tingling, wrist
HDG 54–55 1.66 50 Tingling, palm
HDG 55–56 1.2 50 Tingling, palm
HDG 56–57 1.8 50 Tingling, palm
HDG 57–58 5.7 50 Tingling, palm
HDG 71–72 5.71 50 Tingling, dorsal surface below digit 5
HDG 72–73 0.85 50 Tingling, dorsal surface below digit 5
HDG 85–86 1.7 50 Tingling, Digit 3, inside surface
HDG 86–87 2.38 50 Tingling, Digit 3, inside surface
HDG 101–102 1.8 50 Tingling, Digits 2–3
HDG 102–103 2.1 50 Tingling, Digits 2–3
HDG 103–104 1.2 50 Tingling, Digits 2–3
HDG 104–105 2.08 50 Tingling, Digits 2–3
HDG 116–117 5 50 Tingling, Digit 2
HDG 117–118 1.95 50 Tingling, Digit 2
HDG 147–148 1.95 50 Tingling, thumb (dorsal on knuckle)
HDG 148–149 3.43 50 Tingling (dorsal on knuckle)
HDG 149–150 2.45 50 Tingling (dorsal on knuckle)