Table 1. Summary of Pseudoequilibrium CO2 Uptake at 20 and 25 °C and 400 ppm (Measured by the Volumetric System, SAP).

  –20 °C
25 °C
      adsorption rate (mmol/g/min)a
    adsorption rate (mmol/g/min)a
adsorbent (powders) CO2 uptake (mmol/g) amine efficiency initial after 2 h CO2 uptake (mmol/g) amine efficiency initial after 2 h
MIL-101(Cr) 0.01 ± 0.008       0.0008 ± 1.46 × 10–4      
MIL-101(Cr) _10 wt % PEI 0.05 ± 0.004 0.02     0.006 ± 9.29 × 10–4 0.002    
MIL-101(Cr) _30 wt % PEI 0.78 ± 0.03 0.11 0.018 2.13 × 10–4 0.24 ± 0.02 0.03 0.021 1.05 × 10–4
MIL-101(Cr) _50 wt % PEI 1.64 ± 0.17 0.13 0.015 6.21 × 10–4 1.81 ± 0.17 0.14 0.016 4.75 × 10–4
MIL-101(Cr) _10 wt % TEPA 0.02 ± 0.005 0.01     0.002 ± 6.93 × 10–4 0.0005    
MIL-101(Cr) _30 wt % TEPA 1.12 ± 0.02 0.14 0.021 2.66 × 10–4 0.39 ± 0.12 0.05 0.022 2.54 × 10–5
MIL-101(Cr) _50 wt % TEPA 1.26 ± 0.28 0.10 0.012 5.71 × 10–4 2.14 ± 0.12 0.16 0.017 2.70 × 10–4
a

The adsorption rate was obtained based on the TGA/DSC data shown in Figure S4.