Skip to main content
. 2022 Feb 16;12:829041. doi: 10.3389/fonc.2022.829041

Table 2.

Predictive performance of each model for HER2.

Prediction target AUC Accuracy Sensitivity % Specificity % PPV % NPV %
Clinical model training set 0.55 68.52% 52.94% 75.68% 50.01% 77.78
Clinical model validation set 0.51 63.89% 54.55% 68.02% 42.86% 77.27%
Radiomics model training set 0.78 71.29% 55.88% 78.38% 54.29% 79.45%
Radiomics model validation set 0.74 72.22% 72.72% 72.00% 53.33% 85.71%
Deep learning model training set 0.87 85.19% 73.53% 90.54% 78.12% 88.16%
Deep learning model validation set 0.84 80.56% 72.73% 84.00% 66.67% 87.5%