Skip to main content
. 2022 Mar 2;36:100482. doi: 10.1016/j.sbsr.2022.100482

Table 1.

Virus recovery using different methods for concentrating virus from wastewater.

Method Sample type Materials/condition Time Virus Virus recovery percentage Ref
Adsorption extraction method Wastewater
Inoculated with virus
  • pH 4–6.9

  • Addition of MgCl2

  • 0.45 μm Electronegative membrane

< 30 min Murine Hepatitis Virus (MHV)
Seeded into wastewater
26.7 ± 15.3%
(Acidification of sample)
65.7 ± 23%
(pre-treatment with MgCl2)
[49,75,99]
Wastewater
Inoculated with virus
  • Aluminum based adsorption-precipitation

  • Beef extraction solution

  • Centrifugation

< 2 h SARS-CoV2
Mengovirus (MgV)
PEDV strain CV777
30.2 ± 17.7%
6.8 ± 4.8%
<2%
[91]
Influent wastewater collected from wastewater plant
  • pH 6.0

  • Aluminum hydroxide (AlOH3) precipitation

  • Beef extraction solution

  • Centrifugation

< 2 h MgV 0.02–4.3% [77,100]
Biobanked influent water samples inoculated with viruses
  • pH 6.0

  • Aluminum hydroxide (AlOH3) precipitation

  • Beef extraction solution

  • Centrifugation

< 2 h Porcine epidemic diarrhea virus (PEDV) strain CV777, enveloped virus
Non-enveloped virus, Mengovirus (MgV)
PEDV:
11 ± 3.5% (Influent water)
3.3 ± 1.6% (Effluent water)
MgV:
11 ± 2.1% (Influent water)
6.2 ± 1.0%(Effluent water)
[77]
Ultracentrifugation Influent wastewater collected from wastewater plant Centrifugation
140,000 ×g for 2 h 20 min
120,000 ×g for 30 min
229,600 ×g for 1 h
<5 h Non-enveloped virus, MgV 8.04–25.72% [77]
Wastewater
From water treatment plant
150,000 ×g at 90 min <2 h SARS-CoV-2 12% [35,80]
Wastewater Centrifugation
100,000 ×g for 1 h
12,000 ×g for 15 min
< 2 h Murine Hepatitis Virus (MHV)
Seeded into wastewater
35.5 ± 12.1% [76]
Raw sewage water from sewage treatment plant 100,000 ×g for 1 h
12,000 ×g for 15 min
100,000 ×g for 1 h
< 2 h Rotavirus (RV-A)
Bacteriophasge (PP7)
Range 34%–67%
Mean: 47%
[101]
Ultrafiltration Wastewater 10, 30 and 100 kDa membrane filter
PEG precipitation
CoV 33–42% [81,82]
Wastewater
From water treatment plant seeded with viruses
CP-Select (Concentration pipette ultrafiltration tips, InnovaPrep)
Centricon® Plus 70 centrifugal ultrafiltration devices (CeUF)
< 2 h Bacteriophage MS2
Murine hepatitis coronavirus (MHV)
CP-Select
MS2: 27.72 ± 24.4%
MHV: 7.51 ± 6.14%
CeUF
MS2: 26.34 ± 22.71%
MHV: 24.07 ± 14.48%
[81]
Wastewater influent from water treatment plant Centricon® Plus 70 centrifugal ultrafiltration devices (CeUF) ~ 1 h Mengovirus 17.5–100.5% [83]
Wastewater CP-Select (Concentration pipette ultrafiltration tips, InnovaPrep)
Electronegative membrane (EM)
< 1 h Bovine
Coronavirus
CP-Select: 5.5 ± 2.1%
EM:
4.8 ± 2.8%
[102]
Wastewater Americon Ultra-15(30 K)
Centricon plus-70
<1 h Murine Hepatitis Virus (MHV)
Seeded into wastewater
56.7 ± 32.3%
28.0 ± 9.1%
[49,103]
Precipitation Wastewater
Inoculated with virus
10% PEG8000
2% NaCl w/v
< 1 h Murine Hepatitis Virus (MHV)
Seeded into wastewater
44.0 ± 27.7% [84]
Grab wastewater
Inoculated with virus
PEG8000(20%)
25 mL of Tris Glycine-Beef Extract buffer (TGEB)
NaCl 0.3 M
Overnight incubation SARS-CoV2
Mengovirus (MgV)
PEDV strain CV777
52.8 ± 18.2%
11.1 ± 4.9%
2.6%
[91]
Grab wastewater from wastewater treatment plant PEG8000 and NaCl2 <24 h F-phage ~10% [87]
Grab wastewater from wastewater treatment plant Pre-centrifugation
PEG8000 and 10%NaCl2
Overnight incubation
<24 h
Bacteriophage
MS2
Pseudomano
Phage
Ҩ6
27.5% -77.6%
29.8%–49.8%
[88]