TABLE III.
Effect of 3D Registration on Mean Symmetric Surface Distance (MSD) Between Manually Drawn Contours of End-Systolic and End-Diastolic Cardiac MRI. The Table Compares the SynthMorph (sm-Shapes) and VoxelMorph (vm-ncc) Models Performing Best At This Task Despite Optimization for Brain Registration, Without Retraining. A Reduction in MSD Translates to Better Alignment of the Left Ventricular Structures. SD Abbreviates Standard Deviation, and We Highlight the Best Result for Each Set of Contours in Bold
Endocardium | Epicardium | |||
---|---|---|---|---|
SynthMorph | VoxelMorph | SynthMorph | VoxelMorph | |
Pairs improved | 29/33 (88%) | 28/33 (85%) | 28/33 (85%) | 25/33 (76%) |
Mean ± SD (mm) | −0.8 ± 0.1 | −0.7 ± 0.1 | −0.6 ± 0.1 | −0.2 ± 0.1 |
Mean ± SD (%) | −10.2 ± 1.6 | −9.0 ± 1.9 | −11.6 ± 1.5 | −4.3 ± 1.4 |
Best pair (%) | −35.4 | −33.8 | −29.6 | −22.5 |
Worst pair (%) | +3.9 | +6.1 | +6.0 | +13.2 |