Skip to main content
. 2022 Mar 3;178:107321. doi: 10.1016/j.microc.2022.107321

Table 2.

Validation parameters of the method for the studied analytes in rat plasma.

Parameter Hydroxychloroquine Favipiravir Oseltamivir Remdesivir
Linear range (ng/mL) 5–100 50–1000 5–100 10–100
Mean ± Standard deviation (S.D) 99.75 ± 0.75 98.01 ± 1.41 99.63 ± 1.31 100.04 ± 1.67
R.S.D* 0.75 0.14 1.31 1.67
Regression Equation Y = 0.0277 X -0.0079 Y = 0.0003X + 0.021 Y = 0.0235X + 0.1993 Y = 0.0197X ± 0.1648
Correlation Coefficient (r) 0.9999 0.9998 0.9999 0.9999
Intraday precision (%R.S.D) 0.83 0.47 2.30 1.10
Interday Precision (%R.S.D) 0.60 0.85 0.52 0.55
Limit of Detection (L.O.D)** (ng/mL) 0.11 10.00 0.92 1.71
Limit of Quantitation (L.O.Q)*** (ng/mL) 0.36 33.33 3.07 5.72

LOD and LOQ are determined based on signal to noise ratio.

RSD*: relative standard deviation before

LOD** =3 × S/N.

LOQ***=10 × S/N.