Skip to main content
. 2022 Feb 18;13:817072. doi: 10.3389/fneur.2022.817072

Table 2.

Efficacy.

Target vessel diameter in DSA PtiO2 (mmHg) TCD (cm/sec) CTP (no. of ROIs with MTT < 6.5)
Patient No. Baseline (mm) After titration (% from baseline) 24 h (% from baseline) 48 h (% from baseline) Baseline After titration 4 h 12 h 24 h 48 h Baseline After titration 4 h 12 h 24 h 48 h Baseline Scan 1 Scan 2
1 2.40 2.4 (0) 2.01 (−16.3) 2.1
(−12.5)
27.0 6.2 34.2 28.9 24.9 32.6 239 199 109 96 180 103 31 15
2 1.6 1.8 (12.5) 0.9 (−43.8) 1
(−37.5)
8.0 10.1 15.7 21.4 22.1 89 147 120 135 139 32 8a
3 0.96 1.64 (70.8) 2.14 (122.9) 30.7 46.4 47.6 38.5 45.7 91 57 94 81 90 31 15b
4 1 0.9
(−10.0)
0.8 (−20.0) 20.7 27.3 27.4 26.4 NA NA NA NA NA
5 0.88 0.95 (8.0) 0.9 (2.3) 0,73
(−17.0)
39.3 45.5 52.5 33.0 27.9 17.9 74 68 60 130 97 130 11 30 24
6 1.51 1.49
(−1.3)
1,5 (−0.7) 28.4 31.8 31.7 37.3 52.4 41 24 35 22 38 3 0
7 0.67 0.92 (25.0) 1.61 (140.3) 19.8 24.6 26.6 30.4 38.3 140 113 66 46 59 17 13

DSA, digital subtraction angiography; PtiO2, brain tissue oxygen; TCD, transcranial Doppler; CTP, computed tomography perfusion; ROI, region of interest; MTT, mean transit time;

a

CTP was performed one day after iNO cessation;

b

CTP was performed 2 days after iNO cessation. Green color indicates that the respective endpoint was reached.