Skip to main content
. Author manuscript; available in PMC: 2023 Mar 1.
Published in final edited form as: Adv Mater. 2022 Jan 24;34(9):e2108021. doi: 10.1002/adma.202108021

Figure 2. Optimal operational condition.

Figure 2.

(a) Schematic illustration of the governing operational parameters in the dual regime spray process. (b) Effect of the governing operational parameters on spray resolution. (c) Representative experimental and CFD results of the spray flow. (d) Mass load, penetration depth, and electrical resistance of test units as a function of atomization pressures and spray distances.