Acquisition parameters for RT and CINE CMR.

1.5 T
3 T
CINE RT CINE RT
Number of images 25 344 25 80–600
Slice thickness [mm] 8 8 6 6
Field-of view [mm2] 380 × 285a 256 × 256 380 × 256a 256 × 256
Matrix size [pixel] 256 × 192a 144 × 144 256 × 192a 160 × 160
Spatial resolution [mm3] 1.5 × 1.5 1.8 × 1.8 1.3 × 1.3 1.6 × 1.6
Flip angle [degree] 64° 55°a 53° 30°a
Echo time [ms] 1.36 1.54 1.51 1.28
Temporal resolution [ms] 38.4a
(16.6 – 62.2)
40.7 41.4a (16.56 – 62.2) 33
a