Table 1. Overview of X-ray parameters for various example settings on the SPB/SFX instrument.

The pulse energies in settings 2–4 are comparable as the accelerator is usually running at 2.26 MHz and electron bunches are delivered interleaved to SASE1 and SASE3 (i.e. maximum 1.13 MHz delivered to each of SASE1 and SASE3). The number of X-ray pulses per 10 Hz train can be varied, leading to different intra-train repetition rates.

  Example values
Parameter 1 2 3 4
Pulse duration (fs) ca 100
Photon energy (keV) 3–16 9.3 9.3 9.3
Pulse energy (mJ) 4 1–2 1–2 1–2
Beam size (µm) ca 3
Photon flux (photons pulse−1) 1.0 × 1012
Photon flux (photons s−1) 2.7 × 1016 1.4 × 1016 6.8 × 1015 2.0 × 1015
Brilliance [photons s−1 mm−2 mrad−2 (0.1% bandwidth)−1] 5 × 1033
No. of pulses per train 2700 1350 352 202
Time between two pulses (ns) 221.6 443.3 886.5 1773.0
Duration of pulse train (µs) 598 598 312 358
Intra-train rep. rate of pulses (MHz) 4.51 2.26 1.13 0.564
Time between two trains (ms) 100
Repetition rate of trains (Hz) 10
No. of pulses per second 27000 13500 3520 2020
Jet gap-to-gap spacing (µm) ∼11 ∼22 44 ∼88
Jet velocity (m s−1)     49.6  

Observed spacing between two gaps along the irradiated liquid jet (displacement between two pulses) in 1.13 MHz mode.