Skip to main content
. 2022 Mar 9;10:e13071. doi: 10.7717/peerj.13071

Table 2. LV hemodynamic measurements.

LVSP (mmHg) LVEDP (mmHg) +dp/dt (mmHg/s) −dt/dt (mmHg/s) Tau (ms)
Control 135 ± 25 2.5 ± 2.2 8059 ± 2028 −6864 ± 1991 13.7 ± 2.7
Equal 143 ± 11 3.2 ± 1.9 8056 ± 888 −7322 ± 814 13.1 ± 1.6
Splenda 146 ± 19 6.1 ± 2.9* 7804 ± 1005 −6817 ± 579 14.5 ± 1.4

Notes.

LVSP
left ventricular systolic pressure
LVEDP
LV end-diastolic pressure
+dp/dt
maximal positive change in pressure over time
−dp/dt
maximal negative change in pressure over time
Tau
Left ventricular relaxation time constant
*

P < 0.05 versus Control.