German Oncology Center (GOC) dosimetric constraints for HDR liver BT.

Target/OARs Constraints used in clinical studies GOC Constraints GOC Special considerations
PTV (Target) D100% = PD (11, 25, 30, 41) V100% > 95% PD: 25Gy
Healthy liver tissue (Liver-GTVs) V5Gy < 2/3 liver volume (11, 25, 30, 41, 42) V10Gy < 2/3 liver volume and 700cc For Re-irradiation*: V40Gy (ΣEQD3Gy2) < 2/3 liver volume and 700cc
V10Gy < 2/3 liver volume (43)
Esophagus/Stomach/Duodenum/Jejunum/Ileum D1cc < 15Gy (11, 27, 30, 44, 45) D1cc < 15Gy For Re-irradiation*: D1cc < 85Gy( Σ EQD3Gy2)
D1cc < 12Gy (46)
Dmax < 15Gy (47)
Dmax < 14Gy (42)
Colon D1cc < 15Gy (11, 30) D1cc < 15Gy
Dmax < 18Gy (42)
Spinal Cord D1cc < 8Gy (11, 30) D1cc < 14Gy For Re-irradiation*: D1cc < 75Gy( Σ EQD3Gy2)
Dmax < 15Gy (47)
Kidneys (for GOC: individual and combined) V7Gy < 2/3 kidney volume (43) D1cc < 18Gy
D200cc < 10Gy
Dmean < 6Gy
For Re-irradiation*: D1cc < 90Gy(ΣEQD3Gy2)
D200cc < 40Gy(ΣEQD3Gy2)
Dmean < 16Gy(ΣEQD3Gy2)
Thoracic Wall No constraint D1cc < 23Gy For Re-irradiation*: D1cc < 110Gy(ΣEQD3Gy2)
Great Vessels No constraint D1cc < 27Gy For Re-irradiation*: D1cc < 240Gy(ΣEQD3Gy2)
Gallbladder Dmax < 20Gy (42) No constraint Mandatory reporting of D1cc and Dmean