Table 1.
Cryo-EM data collection, refinement and model validation statistics.
Item | CCHFV sGc-trimer |
---|---|
Data collection and processing | |
Microscope | JEOL CRYO ARM 300 |
Voltage (kV) | 300 |
Magnification | 80,000 × |
Defocus range (μm) | 0.5 to 2.5 |
Pixel size (Å) | 0.61 |
Image stacks (no.) | 3330 |
Frames per stack | 40 |
Total dose per movie (e−/Å2) | 48 |
Final particle images (no.) | 187,292 |
Symmetry imposed | C3 |
Map resolution (Å) | 2.8 |
FSC threshold | 0.143 |
Map-sharpening B factor (Å2) | −141 |
Model refinement | |
Composition | |
Chains | 3 |
Non-hydrogen atoms | 10,143 |
Protein residues | 1296 |
B factors for protein (Å2) | 43.91 |
R.m.s. deviations | |
Bond lengths (Å) | 0.006 |
Bond angles (°) | 0.765 |
Validation | |
MolProbity score | 1.87 |
Clashscore | 7.79 |
Poor rotamers (%) | 0.00 |
Ramachandran plot | |
Favored (%) | 93.06 |
Allowed (%) | 6.94 |
Disallowed (%) | 0.00 |
CCHFV, Crimean-Congo hemorrhagic fever virus; sGc-trimer, trimer of the soluble Gc ectodomain; R.m.s, root mean square.