Study | Reason for exclusion |
---|---|
Cheng 2011 | Fracture location is on the distal third of the tibia diaphysis, which is outside of the scope of review |
Dai 2009 | The study design was not explicitly stated with no description of allocation method. It seems to be a retrospective study. Also, the fracture location was not clearly defined: the study included AO/OTA type A, B and C fractures, without mentioning whether type 42 or type 43 fracture was included. If type 42 fractures were included, they are outside the scope of this review. If type 43 fractures were included, a high proportion of intra‐articular fractures (type B+C, 21/25 versus 15/20) were present, which are also outside the scope of this review |
Hontzsch 2014 | This RCT of two types of locking systems for intramedullary nailing included 75 participants in the experimental group and 67 participants in the control group. However, only 3/75 versus 0/67 were classified as AO/OTA 43 fractures; the rest being AO/OTA 42 fractures, which are outside the scope of this review |
Li 2014 | The study focused on distal tibial shaft (AO 42) fractures, which was beyond the scope of review |
Liu 2014 | The fracture location of the study was not clearly defined: the study included AO/OTA type A, B and C fractures, without mentioning whether type 42 or type 43 fracture was included. If type 42 fractures were included, they are beyond the scope of this review. If type 43 fractures were included, a high proportion (> 25%) of intra‐articular fractures (type B+C/total: 26/68) was present; which also is a reason for exclusion |
Ristiniemi 2011 | Retrospective study design. The study design is outside the scope of review |
Shon 2012 | Retrospective cohort study design. The study design is outside the scope of review |
Sun 2014 | The study focused on distal tibial shaft (AO 42) fractures, which are outside the scope of review |
Vallier 2011 | This was an RCT but the fracture location was 4 cm to 11 cm from the distal tibia plafond; which is outside the scope of this review |
Vallier 2012 | The study focused on extra‐articular distal tibia shaft fractures (OTA 42), which was beyond the scope of review |
Yang 2006 | Retrospective study design. The study design is outside the scope of this review |
Zou 2012 | RCT but the trial included distal tibial shaft fractures (AO/OTA types 42 A, 42B, and 42C fractures), which are outside the scope of this review |
Zou 2013 | RCT but the trial included distal tibial shaft fractures (AO/OTA types 42 A, 42B, and 42C fractures), which are outside the scope of this review |
AO/OTA: Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association
RCT: randomised controlled trial