Table 1.

Eustachian tube parameters for all participants during the Frenzel maneuver Eustachian tube opening pressure (ETOP, in mbar), Eustachian tube opening duration (ETOD, in seconds), and Eustachian tube opening frequency (ETOF, in openings per minute) for all 22 ears mean values ± standard deviation are given with 95% confidence intervals and median

ID ETOP ETOD ETOF
Mean ± std 95% CI Median Mean ± std 95% CI Median Median
1 38.3 ± 29.7 21.2–55.5 31.8 4.9 ± 3.3 2.9–6.8 4.6 3
2 31.2 ± 76.6 −8.2–70.6 12 3.3 ± 1.1 2.7–3.9 3.1 4.25
3 69.6 ± 17.3 57.2–82.0 64 3.2 ± 0.9 2.5–3.8 3.0 2.5
4 183.0 ± 23.8 145.2–220.8 184 2.5 ± 0.8 1.2–3.9 2.3 1
5 9.0 ± 6.7 6.3–11.7 8 1.4 ± 1.0 1.0–1.8 0.9 6.5
6 58.4 ± 35.9 32.7–84.1 47.5 2.3 ± 0.7 1.7–2.8 2.5 2.5
7 10.1 ± 5.7 8.3–12.0 12 1.8 ± 0.7 1.5–2.0 1.8 9.75
8 21.2 ± 6.0 18.8–23.7 20.5 2.4 ± 0.6 2.2–2.7 2.3 6.5
9 27.0 ± 10.6 21.7–32.3 27 3.1 ± 1.0 2.6–3.6 3.2 4.5
10 8.9 ± 2.5 8.4–9.5 9 0.6 ± 0.2 0.6–0.6 0.6 17.5
11 20.8 ± 6.0 18.4–23.2 22 2.7 ± 1.1 2.3–3.1 2.7 6.8
Total 22.7 ± 33.7 18.6–26.8 13 2.0 ± 1.6 1.8–2.2 1.8 4.5