Skip to main content
. 2022 Feb 3;132(3):888–901. doi: 10.1152/japplphysiol.00175.2021

Table 2.

Hemodynamic parameters in Sham and pulmonary artery-banded rats

Hemodynamics Sham
PAB
Intact male Intact female OVX female Intact male Intact female OVX female
Peak systemic pressure, mmHg 110 ± 5 116 ± 5 111 ± 8 122 ± 8 119 ± 5 115 ± 8
RV end-diastolic pressure, mmHg 4.50 ± 0.72 3.65 ± 0.38 3.00 ± 0.44 6.48 ± 0.71 6.46 ± 1.28* 4.46 ± 0.84
RV end-systolic volume index, μL/g 0.26 ± 0.03 0.25 ± 0.04 0.24 ± 0.05 0.54 ± 0.04* 0.49 ± 0.09* 0.32 ± 0.07
RV end-diastolic volume index, μL/g 0.94 ± 0.06 0.99 ± 0.11 0.71 ± 0.09 1.04 ± 0.06 1.14 ± 0.11 0.61 ± 0.08†‡

Values are presented as means ± SE. PAB, pulmonary artery banding; RV, right ventricle; Sham, sham surgery. n = 8–10 animals per group. P < 0.05 for *PAB vs. respective Sham, †female [intact or ovariectomized (OVX)] vs. male, and ‡OVX vs. intact female (2-way ANOVA with Tukey’s honestly significant difference multiple comparison correction).