Table 1.

Aerosolized Fluorescein Collected by BioSampler and Measured Using Fluorometric Analysis.

Experiment Position Mean Fluorescence, RFU SD % Reduction
Air-turbine handpiece: open-plan setting
 No LEV (suction), n = 3 Operator 9,878 4,478 Reference
0.5 m 1,514 1,153 Reference
1.0 m 581 613 Reference
2.0 m 166 116 Reference
 LEV and suction, n = 3 Operator 905 402 90.8
0.5 m 148 39 90.2
1.0 m 99 50 82.9
2.0 m 42 21 74.7
Ultrasonic scaler: single-surgery setting
 No LEV, no suction, n = 3 Chest 1,681 1,184 Reference
0.5 m 560 464 Reference
1.0 m 187 68 Reference
2.0 m 251 61 Reference
 Suction only, n = 3 Chest 9 17 99.5
0.5 m 1 3 99.9
1.0 m 1 2 99.3
2.0 m 1 3 99.5
 LEV only, n = 3 Chest 22 41 98.7
0.5 m 1 0 99.9
1.0 m 1 1 99.7
2.0 m 0 a 2 100.0 a
 LEV and suction, n = 3 Chest 3 2 99.8
0.5 m 2 2 99.6
1.0 m 2 1 98.7
2.0 m 3 1 98.7

Data adjusted for background fluorescence by subtraction of the background reading from all data (open-plan setting: 25.2 relative fluorescence units [RFU], n = 12; single-surgery setting: 25.8 RFU, n = 12). All air-turbine experiments also used dental suction.

LEV, local exhaust ventilation.

a

Actual reading was below zero (–1 RFU) after subtraction of background reading but limited to zero for this table.