Table 1.
Experiment | Position | Mean Fluorescence, RFU | SD | % Reduction |
---|---|---|---|---|
Air-turbine handpiece: open-plan setting | ||||
No LEV (suction), n = 3 | Operator | 9,878 | 4,478 | Reference |
0.5 m | 1,514 | 1,153 | Reference | |
1.0 m | 581 | 613 | Reference | |
2.0 m | 166 | 116 | Reference | |
LEV and suction, n = 3 | Operator | 905 | 402 | 90.8 |
0.5 m | 148 | 39 | 90.2 | |
1.0 m | 99 | 50 | 82.9 | |
2.0 m | 42 | 21 | 74.7 | |
Ultrasonic scaler: single-surgery setting | ||||
No LEV, no suction, n = 3 | Chest | 1,681 | 1,184 | Reference |
0.5 m | 560 | 464 | Reference | |
1.0 m | 187 | 68 | Reference | |
2.0 m | 251 | 61 | Reference | |
Suction only, n = 3 | Chest | 9 | 17 | 99.5 |
0.5 m | 1 | 3 | 99.9 | |
1.0 m | 1 | 2 | 99.3 | |
2.0 m | 1 | 3 | 99.5 | |
LEV only, n = 3 | Chest | 22 | 41 | 98.7 |
0.5 m | 1 | 0 | 99.9 | |
1.0 m | 1 | 1 | 99.7 | |
2.0 m | 0 a | 2 | 100.0 a | |
LEV and suction, n = 3 | Chest | 3 | 2 | 99.8 |
0.5 m | 2 | 2 | 99.6 | |
1.0 m | 2 | 1 | 98.7 | |
2.0 m | 3 | 1 | 98.7 |
Data adjusted for background fluorescence by subtraction of the background reading from all data (open-plan setting: 25.2 relative fluorescence units [RFU], n = 12; single-surgery setting: 25.8 RFU, n = 12). All air-turbine experiments also used dental suction.
LEV, local exhaust ventilation.
Actual reading was below zero (–1 RFU) after subtraction of background reading but limited to zero for this table.