Fig. 4.

Fig. 4

a Process diagram of the transformation of measurement data (geometry, IOP, deformation contours) into the input data required for the inverse method (stress-free geometry, IOP including the IOP change, full-field displacement) using the mechanical morphing approach and b illustration of the principle of the mechanical morphing approach. Virtual stamps force the corneal model to deform