Skip to main content
. 2022 Mar 23;12:5038. doi: 10.1038/s41598-022-09066-3

Table 2.

I-optimal design layout and experimental results.

Factor 1 Factor 2 Response 1 Response 2 Response 3 Response 4
Run A: Temperature B: Samples Gas Biocrude Aqueous Hydrochar
°C Wt% Wt% Wt% Wt%
1 250 CR 34.01 12.64 17.23 36.12
2 250 PR 22.91 13.9 13.55 49.64
3 350 PL 31.07 23.73 9.65 35.55
4 350 CL 37 22.39 12.48 28.13
5 300 CR 34.99 14.19 15.85 34.97
6 350 CR 36.77 16.41 14.65 32.17
7 300 PS 25.81 17.1 17.11 39.98
8 250 CL 36.89 19.14 11.08 32.89
9 300 CS 37.74 17 12.6 32.66
10 300 CS 38.01 17.11 12.74 32.14
11 300 CL 36.22 21.01 12.58 30.19
12 300 CR 35.1 14.25 15.76 34.89
13 250 PS 23.14 17.51 19.09 40.26
14 350 PS 30.22 20.04 13.66 36.08
15 300 PR 24.23 16.01 13.16 46.6
16 250 CS 36.07 15.5 13.53 34.9
17 350 PR 25.6 17.51 11.1 45.79
18 350 CS 39.16 17.99 12.8 30.05
19 300 CL 36.07 21.12 12.5 30.31
20 300 PL 28.31 28.2 10.5 32.99
21 250 PL 25.06 19.02 19.16 36.76
22 300 PR 25 16.78 12.34 45.88
23 300 PS 25.6 16.51 17.69 40.2