Validity and reliability.

Study Comparison assessment Validity Reliability
Adams [46] a
  • Hand tremor (AUCb=0.76)

Aghanavesi et al [48] MDS-UPDRSc
  • Finger tapping (r=0.23)

  • Handwriting (r=0.46)

Interrater reliability:
  • Finger tapping (r=0.61)

  • Handwriting (r=0.65)

Akram et al [38] MDS-UPDRS
  • Finger tapping (r=−0.49; P<.001)

Albani et al [73] MDS-UPDRS
  • Finger tapping (ICCd=0.73)

Amano et al [69] In-clinic assessment
  • Finger dexterity (r=0.99)

  • Whole hand grasp (r=0.99)

  • Pincer grasp (r=0.99)

Interrater reliability:
  • Finger dexterity (r=0.99)

Arora et al [70] MDS-UPDRS
  • Finger tapping (mean error of 1.26 UPDRSe points)

Arroyo-Gallego et al [49] MDS-UPDRS
  • Finger tapping (AUC=0.85; P<.001)

Bazgir et al [50] MDS-UPDRS
  • Hand tremor (97% accuracy)

Bochniewicz et al [82] ARATf
  • IADLg (r=−0.14; P=.70)

Boroojerdi et al [37] MDS-UPDRS
  • Finger tapping (r=0.291)

  • Hand tremor (r=0.746)

Burdea et al [71]
Cabrera-Martos et al [67] In-clinic assessment Interrater reliability:
  • Finger dexterity (r=0.89)

  • Finger tapping (r=1.0)

  • Hand tremor (r=0.99)

Cai et al [19] MDS-UPDRS
  • Hand tremor (r2=0.95)

Channa et al [20] MDS-UPDRS
  • Hand tremor (91.7% accuracy)

Cole et al [21] MDS-UPDRS
Creagh et al [59] 9HPTh
  • Handwriting: dominant hand (r2=0.39) and nondominant hand (r2=0.41)

Cunningham et al [74]
Dai et al [22] MDS-UPDRS
  • Finger tapping (r=−0.970; P<.01)

  • Hand tremor (r=0.93; P<.001)

Interrater agreement (Kendall W):
  • Finger tapping (0.86)

  • Hand tremor (0.84)

Dubuisson et al [91] 9HPT
  • Finger dexterity (r=0.9; P<.001)

Ferreira et al [23] MDS-UPDRS
Giancardo et al [39] MDS-UPDRS
  • Finger tapping (AUC=0.75)

Giuffrida et al [24] MDS-UPDRS
  • Hand tremor (r=0.89)

Goetz et al [75] MDS-UPDRS
Halloran et al [25] CAHAIi
  • ADLj (r= 0.63; P<.001)

Heijmans et al [26] ESMk app (tremor questionnaire)
  • Hand tremor (r=0.43)

Hoffman et al [68] In-clinic assessment
  • Hand tremor (83.3% agreement)

  • Handwriting (41.6% agreement)

Interrater reliability:
  • Finger dexterity (r=0.99)

Hssayeni et al [27] MDS-UPDRS
  • Hand tremor (r=0.84)

Iakovakis et al [52] MDS-UPDRS
  • Finger tapping (AUC=0.92)

Iakovakis et al [51] MDS-UPDRS
  • Finger tapping (r=0.66)

Jeon et al [28] MDS-UPDRS
  • Hand tremor (85.5% agreement)

Jha et al [60] MDS-UPDRS
  • Hand tremor (κ=0.68; P<.001, substantial)

  • Finger tapping (κ=0.54; P<.001, moderate)

Interrater agreement:
  • Hand tremor (96%)

  • Finger tapping (50%)

Kim et al [29] MDS-UPDRS
  • Hand tremor (85% accuracy)

Interrater reliability:
  • Hand tremor (r=0.78)

Kleinholdermann et al [85] MDS-UPDRS
  • Finger tapping (r=0.445)

Kostikis et al [81] MDS-UPDRS
  • Hand tremor,: right hand (r=0.75; P<.001) and left hand (r=0.85; P<.001)

Lam et al [41] 9HPT
  • Finger dexterity (r=−0.553)

Test–retest reliability:
  • Finger dexterity (ICC 0.601)

Lee et al [53] MDS-UPDRS
  • Finger tapping (AUC=0.92, 95% CI 0.88-0.96)

Lee et al [84] FMAl
  • Whole hand grasp (92% accuracy)

Lee et al [54] MDS-UPDRS
Lin et al [88]
Lipsmeier et al [61] MDS-UPDRS
  • Finger tapping (t=2.18; P=.03)

  • Hand tremor (t=2.17; P=.03)

Test–retest reliability:
  • Finger tapping (ICC=0.64)

  • Hand tremor (ICC=0.90)

Londral et al [47] Test–retest reliability:
  • r=0.96; P=.09

Lopez-Blanco et al [76] MDS-UPDRS
  • Hand tremor (r=0.81; P<.001)

Interrater reliability:
  • Hand tremor (ICC=0.89)

Mahadevan et al [30] MDS-UPDRS
  • Hand tremor (r=0.67; P<.001)

Interrater reliability:
  • Hand tremor (ICC=0.75)

Matarazzo et al [42] UPDRS-3
Memedi et al [77] Visual assessment
  • Handwriting (85% accuracy)

Test–retest reliability:
  • Handwriting (ICC=0.69)

Mera et al [31]
Mitsi et al [65] MDS-UPDRS
Noyce et al [43] MDS-UPDRS
  • Finger tapping (r=0.53)

Orozco-Arroyave et al [62] UPDRS-3
Pan et al [63] MDS-UPDRS
  • Hand tremor (r=0.81)

Papadopoulos et al [40,55] MDS-UPDRS
Powers et al [78] MDS-UPDRS
  • Hand tremor (r=0.72)

Pratap et al [66] Longitudinal Neuro-QoLm scores
  • Finger tapping (β=.40; P<.001)

Prochazka and Kowalczewski [83] ARAT and FMA
  • Finger dexterity (r2=0.49)

  • Whole hand grasp, (r2=0.88)

  • Pincer grasp (r2=0.88)

Test–retest reliability:
  • 0.67% (SD 3.6)

Rigas et al [32] MDS-UPDRS
  • Hand tremor (87% accuracy)

Salarian et al [87] MDS-UPDRS
  • Hand tremor (r=0.87; P<.001)

San-Segundo et al [33]
Sanchez-Perez et al [34] MDS-UPDRS
Schallert et al [56]
Shribman et al [44] 9HPT
  • Finger tapping (r=0.926)

Sigcha et al [79] MDS-UPDRS
  • Hand tremor (r=0.969)

Simonet et al [57] MDS-UPDRS
  • Finger tapping (r=−0.49)

Stamatakis et al [35] MDS-UPDRS
  • Finger tapping (Goodman–Kruskal index=0.961)

Tavares et al [86] MDS-UPDRS
  • Finger tapping (r=0.67; P<.001)

Trager et al [45] MDS-UPDRS
  • Finger dexterity (r=0.14; P=.43)

  • Finger tapping (r=0.58; P<.001)

Westin et al [80] MDS-UPDRS
  • Handwriting (r=0.41)

Test–retest reliability:
  • Handwriting (r=0.71)

Wissel et al [58] MDS-UPDRS
  • Finger tapping (r=0.55)

Test–retest reliability:
  • Finger tapping (r>0.75)

Wu et al [89] MDS-UPDRS
  • Hand tremor (r=−0.798)

Yu et al [72] FMA
  • Finger dexterity (r2=0.70)

  • Pinch strength (r2=0.72)

Zambrana et al [90]
Zhan et al [64] MDS-UPDRS
  • Finger tapping (mean 71%, SD 0.4%)

Zhang et al [36] MDS-UPDRS
  • Hand tremor (85.9% accuracy)

aData unavailable.

bAUC: area under the curve.

cMDS-UPDRS: Movement Disorder Society–Unified Parkinson’s Disease Rating Scale.

dICC: interclass coefficient.

eUPDRS: Unified Parkinson’s Disease Rating Scale.

fARAT: Action Research Arm Test.

gIADL: instrumental activities of daily living.

h9HPT: 9-hole peg test.

iCAHAI: Chedoke Arm and Hand Inventory.

jADL: activities of daily living.

kESM: experience sampling method.

lFMA: Fugl-Meyer Assessment.

mQoL: quality of life.