Comparison of CuO/Cu2O-based non-enzymatic electrochemical glucose sensors.

Electrode Material Substrate Sensitivity
(µA mM−1 cm−2)
Linear Range
(mM)
Applied Potential
(V)
LOD
(µM)
Reference
CuO nanofibers GCE 431.3 0.006–2.5 0.4 0.8 [39]
Cu2O nanocubes SPCE 1040 0.007–4.5 0.7 31 [23]
Cu2O nanocubes/nafion GCE 2864 0.05–5.65 0.7 1.7 [40]
Cu2O NPs/nafion GCE 190 0.05–1.1 0.5 47.2 [41]
Cu2O nanowires Cu foil 4060 0.001–2.0 0.55 0.58 [25]
Cu2O nanowires Cu foam 6680.7 0.001–1.8 0.5 0.67 [42]
CuO/Cu2O nanosheets Cu foil 1541 0.001–4 0.6 0.57 [22]
Cu2O nanoclusters GCE 1082.5 0.1–1 0.35 (DPV) 12 This work
Cu2O nanoclusters Cellulose PE 182.9 0.1–1 0.35 (DPV) 52.7 This work

SPCE = screen printed carbon electrode; NPs = nanoparticles.