Table 7.
The Type of Fault | The Type of Sensor | Diagnostic Accuracy | Diagnostic Precision | Diagnostic Recall |
---|---|---|---|---|
Imbalance fault | Wired | 90.00% | 90.20% | 92.00% |
Wireless | 90.91% | 90.70% | 90.70% | |
Misalignment fault | Wired | 97.37% | 94.44% | 100% |
Wireless | 91.89% | 91.67% | 84.62% | |
Loose fault | Wired | 95.08% | 100% | 91.43% |
Wireless | 80.33% | 91.30% | 83.13% | |
Bearing fault | Wired | 100% | 100% | 100% |
Wireless | N.A. | N.A. | N.A. | |
Cavitation fault | Wired | 85.71% | 100% | 85.71% |
Wireless | N.A. | N.A. | N.A. |