Table 2.
Loss of filtering efficiency after 4 months of samples stored at room temperature (0.01–1.0 m particle size range).
Particle Diameter Range 0.01–1.0 m | |||||||||
---|---|---|---|---|---|---|---|---|---|
Sample | Thickness (m) | Filtration Efficiency (%) 1 | Pressure Drop (mbar) 1 | Filtration Efficiency (%) 2 | Pressure Drop (mbar) 2 | Loss of Efficiency (%) 2 | Filtration Efficiency (%) 3 | Pressure Drop (mbar) 3 | Loss of Efficiency (%) 3 |
M1 | 230 | 89.9 | 0.80 | 87.8 | 0.86 | 2.4 | 87.4 | 0.88 | 2.9 |
M2 | 210 | 85.5 | 0.64 | 85.1 | 0.76 | 0.5 | 80.9 | 0.68 | 5.4 |
M3 | 110 | 78.85 | 0.40 | 77.1 | 0.52 | 2.2 | 59.3 | 0.66 | 24.8 |
M4 | 110 | 76.6 | 0.42 | 65.0 | 0.36 | 15.0 | 63.1 | 0.70 | 17.5 |
M5 | 100 | 71.2 | 0.40 | 67.7 | 0.42 | 4.9 | 58.3 | 0.64 | 18.1 |
M6 | 190 | 82.5 | 0.46 | 70.0 | 0.46 | 15.2 | 63.5 | 0.70 | 23.0 |
1 Initial values. 2 After 2 months. 3 After 4 months.