OAR tolerances for FSRT planning.

Constraint
OAR
Brainstem Dmax ≤ 20Gy
Optic nerves Dmax ≤ 15Gy
Chiasm Dmax ≤ 15Gy
Lens Dmax ≤ 8Gy
Inner ears Dmax ≤ 30Gy
SpinalCord Dmax ≤ 30Gy