Skip to main content
. 2022 Mar 22;14:493–516. doi: 10.2147/NSS.S348795

Table 2.

Sleep Stage Summary Agreement

Stage Device n Device Mean (SD) Reference Mean (SD)
Light Fitbit Inspire HR 106 243.5 (53.0) 189.4 (54.3)
Oura Ring 111 210.8 (66.0) 189.0 (53.9)
Polar Vantage V Titan 103 226.1 (90.5) 190.7 (52.9)
Deep Fitbit Inspire HR 106 70.1 (21.9) 80.1 (29.3)
Oura Ring 111 124.1 (41.7) 81.4 (29.2)
Polar Vantage V Titan 103 104.5 (92.1) 82.8 (28.6)
REM Fitbit Inspire HR 106 92.8 (30.2) 137.2 (54.8)
Oura Ring 111 77.5 (34.8) 132.7 (52.6)
Polar Vantage V Titan 103 87.8 (40.7) 138.2 (54.4)

Notes: Sleep stage summary agreement between devices and reference. The Dreem headband served as reference for all sleep stage outcomes. Results are shown for all devices that output sleep stage classifications. See Table 1 notes for additional table details.

Abbreviations: REM, rapid eye movement; SD, standard deviation.