Skip to main content
. 2022 Feb 4;31(4):268–273. doi: 10.1097/IJG.0000000000001994

TABLE 3.

Statistical Difference Was Demonstrated When Comparing Mean IOP Reduction at Each Follow-up Timepoint

IOP Reduction, mm Hg (mean±SD)
Comparing With Preoperative Baseline IOP TrabEx+ Standalone P * Phaco and TrabEx+ P *
1 wk −13.4±13.4 <0.001 −10.4±14.9 <0.001
3 mo −9.1±13.1 0.002 −13.9±8.6 <0.001
6 mo −13.0±9.0 <0.001 −13.4±9.8 <0.001
12 mo −11.7±7.6 <0.001 −14.8±10.5 <0.001
18 mo −13.7±8.7 <0.001 −13.0±10.8 <0.001
24 mo −12.2±10.3 0.012 −11.7±7.9 0.002
Latest −7.9±13.4 0.004 −12.1±9.8 <0.001
*

Paired-samples t test.

IOP indicates intraocular pressure.