Skip to main content
. 2022 Mar 24;11:e75433. doi: 10.7554/eLife.75433

Table 2. Förster resonance energy transfer (FRET)-state occupancies and rate constants for SΔTM D614.

Data are presented at mean ± standard error determined from the total population of traces analyzed.

SARS-CoV-2 spikes D614 FRET-state occupancies (%) Rate constants (s–1)
Low-FRET (0.35)RBD-up conformation High-FRET (0.65)RBD-down conformation kdown(Low to high FRET) kup(High to low FRET)
Unbound 40 ± 3 60 ± 3 3.8 ± 0.2 2.6 ± 0.2
+ ACE2 66 ± 3 34 ± 3 1.3 ± 0.1 2.2 ± 0.2
+ MAb362IgG1 52 ± 2 48 ± 2 2.2 ± 0.1 2.2 ± 0.1
+ MAb362IgA1 54 ± 2 46 ± 2 1.8 ± 0.1 2.0 ± 0.1
+ REGN10987 52 ± 3 48 ± 3 2.4 ± 0.2 2.2 ± 0.2
+ S309 49 ± 3 51 ± 3 2.3 ± 0.1 2.1 ± 0.1
+ CR3022 54 ± 4 46 ± 4 2.3 ± 0.2 3.1 ± 0.2
+ 4A8 48 ± 2 52 ± 2 2.3 ± 0.1 2.3 ± 0.1
+ 1A9 60 ± 2 40 ± 2 2.2 ± 0.1 3.4 ± 0.2
+ 2G12 59 ± 2 41 ± 2 2.5 ± 0.1 3.4 ± 0.2