Skip to main content
. 2022 Mar 8;9:811492. doi: 10.3389/fcvm.2022.811492

Table 2.

Diagnostic ability of different test modalities for patients with IE.

Test modality Sensitivity Specificity Positive predict value Negative predict value ROC
AUC
ROC
P
Blood culture 29.3%
(0.21–0.39)
100%
(0.72–1.00)
100%
(0.88–1.00)
13.6%
(0.07–0.23)
0.646
(0.601–0.691)
0.112
Valve culture 16.2%
(0.10–0.25)
100%
(0.72–1.00)
100%
(0.79–1.00)
11.7%
(0.06–0.20)
0.581
(0.544–0.617)
0.381
Valve NGS 85.9%
(0.77–0.92)
72.7%
(0.39–0.94)
96.6%
(0.90–0.99)
36.4%
(0.17–0.59)
0.793
(0.651–0.935)
0.001
Combined detection 89.9%
(0.82–0.95)
72.7%
(0.39–0.94)
96.7%
(0.91–0.99)
44.4%
(0.22–0.69)
0.813
(0.672–0.954)
0.001