Skip to main content
. 2022 Mar 16;12:845549. doi: 10.3389/fonc.2022.845549

Table 5.

Pooled diagnostic performance of qualitative USE using only prospective papers. USE, Ultrasound Elastography.

Method Sens, %(CI, %)(I-square, %) Spec, %(CI, %)(I-square, %) PLR(CI)(I-square, %) NLR(CI)(I-square, %) AUC(CI, %)
Qualitative USE 74.4
(71.5–77.2)
(81.7)
82.3
(80.9–83.7)
(94.7)
4.10
(2.98–5.66)
(90.7)
0.30
(0.22–0.40)
(79.8)
87.1
(84.1–90.1)
Semi-quantitative USE 83.9
(81.2–86.2)
(83.9)
87.8
(86.5–88.9)
(90.6)
7.36
(4.78–11.34)
(92.6)
0.16
(0.10–0.27)
(88.4)
94.3
(92.8–0.95.8)
Quantitative USE 78.0
(76.1–79.8)
(55.1)
80.9
(79.5–82.2)
(88.6)
4.60
(3.71–5.70)
(84.0)
0.26
(0.22–0.32)
(63.7)
87.8
(86.3–89.2)