Skip to main content
. 2022 Mar 17;10:782068. doi: 10.3389/fpubh.2022.782068

Table 2.

Number and calculated mass-based aerosol characteristics from fast mobility particle sizer (FMPS) and scanning mobility particle sizer (SMPS) measurements (n = 6 trials/e-liquid).

FMPS SMPS
E-liquid CMD (μm) GSD MMAD (μm) CMD (μm) GSD MMAD (μm)
30:70 PG:VG 0.075 1.004 0.082 0.132 2.6 2.23
30:70 PG:VG w/flavorings 0.060 1.005 0.066 0.141 2.4 1.54
30:70 PG:VG w/nicotine 0.062 1.005 0.068 0.140 2.4 1.52
70:30 PG:VG 0.064 1.004 0.067 0.076 2.6 1.24
70:30 PG:VG w/flavorings 0.073 1.004 0.077 0.078 2.5 1.02
70:30 PG:VG w/nicotine 0.072 1.004 0.076 0.071 2.5 0.93

CMD, count median diameter; GSD, geometric standard deviation; MMAD, mass median aerodynamic diameter; PG, propylene glycol; VG, vegetable glycerin.