Table 1.

Intra-rater reliability (ICC 1.1) for ROM measurements

Test
mean
±SD
(°)
Retest
mean
±SD
(°)
ICC
1.1
(95%
CI)
SEm
(°)
LOA
(°)
Fixed error Proportional bias MDC
(°)
95%
CI
Result Regression
coefficient
Result
Straight leg raise angle 67.3
±19.6
66.6
±19.6
0.939
(0.89,
0.97)
4.87 –8.99
~
10.39
–1.50
~
2.90
No p=0.998 No 13.50
Ankle dorsiflexion angle 11.2
±5.7
10.8
±5.6
0.668
(0.455,
0.809)
3.28 –6.13
~
6.93
–1.09
~
1.89
No p=0.97 No 9.10
Hip internal rotation angle 40.4
±12.0
40.4
±11.6
0.901
(0.821,
0.946)
3.76 –7.50
~
7.45
–1.72
~
1.67
No p=0.59 No 10.41

SD: standard deviation

95% CI: 95% confidence interval

SEm: standard error of the measurement

LOA: limit of agreement

MDC: minimal detectable change

ICC: intraclass correlation coefficient