Skip to main content
. 2022 Mar 18;35:10240. doi: 10.3389/ti.2022.10240

TABLE 3.

Multivariable Cox regression model of risk factors associated with death, graft loss, or death-censored graft loss.

Death Graft loss Death-censored graft loss
HR (95%CI) p HR (95%CI) p HR (95%CI) p
Plasma oxalate >13.0 μmol/L 2.23 (1.24–4.01) 0.008 1.80 (1.09–2.97) 0.021 1.68 (0.78–3.64) 0.188
Recipient age (years) 1.08 (1.06–1.11) <0.001 1.03 (1.01–1.05) 0.001
Donor > 60 years 1.13 (0.55–2.32) 0.731 1.50 (0.80–2.81) 0.205 3.00 (1.27–7.08) 0.012
Living donor 0.36 (0.18–0.70) 0.003 0.43 (0.26–0.72) 0.001 0.45 (0.21–0.93) 0.032
HLA-DR mismatch (1 or 2) 1.10 (0.65–1.85) 0.718 1.81 (1.12–2.93) 0.015 3.64 (1.47–9.01) 0.005
mGFR at 10 weeks (ml/min) 1.00 (0.99–1.02) 0.727 0.99 (0.98–1.01) 0.401 0.99 (0.97–1.01) 0.471
Current smoker at 10 weeks 3.10 (1.69–5.68) <0.001 1.96 (1.15–3.35) 0.014 0.67 (0.20–2.25) 0.516

Abbreviations: HLA-DR, Human Leukocyte Antigen-DR; mGFR, measured glomerular filtration rate. Bold data indicate statistical significant findings.