Skip to main content
. 2022 Apr 1;8:7. doi: 10.1038/s41526-022-00192-w

Table 5.

Improvement of chilldown efficiency by coating.

Reduced-G Ground-G
Case Percent improvement Percent improvement
1 (micro-g) 80 psig, continuous flow 38.6% 18.7%
2 (micro-g) 80 psig 40% DC, 1 s Period 34.1% 31.1%
3 (micro-g) 80 psig 70% DC, 1 s Period 72.0% 19.1%
4 (micro-g) 60 psig, continuous flow 59.3% 31.9%
5 (micro-g) 90 psig, continuous flow 30.2% 20.5%
6 (micro-g) 90 psig 50% DC, 1 s Period 28.2% 22.4%