Skip to main content
. 2022 Apr 2;21:111. doi: 10.1186/s12936-022-04133-6

Table 4.

Diagnosis accuracy compared to nested PCR based on venous blood and DBS as DNA template

DNA template
to PCR
Sensitivity
(95% CI)
Specificity
(95% CI)
PPV
(95% CI)
NPV
(95% CI)
Agreement %
(Kappa)
Venous blood, N = 110
 HRP-2-RDT 17.8 (6.1–29.4) 100 NA NA 66.4 (0.20)
 Microscopy 20.0 (7.8–32.1) 100 NA NA 67.3 (0.22)
 Pan-LAMP 93.3 (85.7–100) 95.4 (90.1–100) NA NA 94.5 (0.88)
 Pf-LAMP 97.4 (92.2–100) 100 NA NA 97.6 (0.84)
DBS, N = 247
 HRP-2-RDT 35.7 (07–64.2) 97.8 (96–99.7) 50 (12.3–87.7) 96.2 (93.7–98.6) 94.3 (0.39)
 Microscopy 57.1 (27.5–86.8) 97 (94.8–99.2) 53.3 (24.7–81.9) 97.4 (95.3–99.4) 94.7 (0.52)
 Pan LAMP 100 78.5 (73.2–83.8) 21.9 (11.5–32.2) 100 79.8 (0.29)
 Pf LAMP ND ND ND ND ND

DNA deoxyribonucleic acid, DBS dried blood spot, HRP-2-RDTs histidine-rich protein 2 based rapid diagnostic tests, Pf Plasmodium falciparum, LAMP loop-mediated isothermal amplification, CI confidence interval, PPV positive predictive value, NPV negative predictive value, NA not applicable, ND not determined