Skip to main content
. 2022 Apr 4;27(8):083010. doi: 10.1117/1.JBO.27.8.083010

Table 3.

Mean run times of the optical and acoustic forward modules and image reconstruction for simulation pipelines with different parameter combinations in seconds (s). The mean time was calculated from the run times of the pipelines: default, bandpass filter, differential mode, and custom. The times are reported for three different spacings: 0.15, 0.35, and 0.55 mm.

Spacing (mm) Optical modeling time (s) Acoustic modeling time (s) Image reconstruction time (s)
0.55 1.19 7.96 2.22
0.35 2.80 8.28 2.21
0.15 27.77 11.62 2.22