Corrosion parameters obtained from potentiodynamic polarization measurements for C-steel in SCPS contaminated with 0.6 M NaCl in the absence and presence of various concentrations of EDTA at 25 °C.

Sample E corr vs. Ag/AgCl (mV) I corr (μA cm−2) β a (mV dec−1) β c (mV dec−1) CR (mpy) IE%
Control −430 12.48 0.235 −0.141 5.69
0.0005 M −455 5.08 0.157 −0.131 2.32 60
0.005 M −383 3.37 0.113 −0.124 1.54 73
0.05 M −368 1.87 0.379 −0.059 0.85 85
0.2 M −477 2.97 0.238 −0.109 1.36 76