Table 1.
Independent variables | Responses | ||||
---|---|---|---|---|---|
Run |
A: ultrasonic power(watt) |
B: Time (Minutes) |
C: Solid/solvent (%) |
Amount of lutein(mg/g) |
Antioxidant activity (%) |
1 | 70 | 12.5 | 15.75 | 21.23 | 91.05 |
2 | 70 | 12.5 | 15.75 | 21.05 | 90.62 |
3 | 50 | 20 | 15.75 | 10.63 | 74.95 |
4 | 70 | 20 | 1.5 | 14.76 | 84.39 |
5 | 70 | 20 | 30 | 16.01 | 86.71 |
6 | 70 | 5 | 1.5 | 10.04 | 78.66 |
7 | 70 | 5 | 30 | 11.81 | 80.93 |
8 | 70 | 12.5 | 15.75 | 21.03 | 92.87 |
9 | 90 | 5 | 15.75 | 9.54 | 76.34 |
10 | 90 | 12.5 | 1.5 | 11.15 | 77.45 |
11 | 70 | 12.5 | 15.75 | 21.06 | 90.05 |
12 | 50 | 12.5 | 30 | 8.91 | 70.54 |
13 | 50 | 5 | 15.75 | 7.14 | 66.17 |
14 | 70 | 12.5 | 15.75 | 20.02 | 90.32 |
15 | 50 | 12.5 | 1.5 | 8.85 | 67.85 |
16 | 90 | 12.5 | 30 | 13.95 | 79.65 |
17 Predicted value Experimental value |
90 70.00 70.00 |
20 12.50 12.50 |
15.75 15.75 15.75 |
10.99 20.87 21.23 ± 0.89a |
73.94 90.98 90.32 ± 1.68b |