Skip to main content
. 2022 Apr 1;85:105994. doi: 10.1016/j.ultsonch.2022.105994

Table 1.

Box-Behnken Design matrix and experimentally obtained results of investigated responses.

Independent variables Responses
Run A:
ultrasonic power(watt)
B:
Time (Minutes)
C:
Solid/solvent (%)
Amount of lutein(mg/g) Antioxidant
activity (%)
1 70 12.5 15.75 21.23 91.05
2 70 12.5 15.75 21.05 90.62
3 50 20 15.75 10.63 74.95
4 70 20 1.5 14.76 84.39
5 70 20 30 16.01 86.71
6 70 5 1.5 10.04 78.66
7 70 5 30 11.81 80.93
8 70 12.5 15.75 21.03 92.87
9 90 5 15.75 9.54 76.34
10 90 12.5 1.5 11.15 77.45
11 70 12.5 15.75 21.06 90.05
12 50 12.5 30 8.91 70.54
13 50 5 15.75 7.14 66.17
14 70 12.5 15.75 20.02 90.32
15 50 12.5 1.5 8.85 67.85
16 90 12.5 30 13.95 79.65
17
Predicted value
Experimental value
90
70.00
70.00
20
12.50
12.50
15.75
15.75
15.75
10.99
20.87
21.23 ± 0.89a
73.94
90.98
90.32 ± 1.68b