A list of studies on the output of extraction columns using the RSM technique.

System Column Variable Response Model R 2, adj-R2 Authors
Effluent of hydrodistillation of fennel–anisole–hexane Rotary disc column (RDC) N [rpm] Efficiency (E) E t = −23.01 + 0.7N − 0.28Qd − 7.57dn − 2.07 × 10−3NQd + 0.048Ndn + 0.01Qddn − 1.87 × 10−3N2 + 0.03Qd2 + 3.12dn2 0.964, 0.980 Eyvazkhani et al.52
Q d [cm3 min−1]
d n a [mm]
Effluent of hydrodistillation of fennel–essential oil–hexane Rotary disc column (RDC) N [rpm] Efficiency (E) E = −0.62922 + 6.3148 × 10−3N + 0.010004Qd + 0.48684dn − 2.00758 × 10−3Ndn − 8.46013 × 10−6N2 − 1.255 × 10−4Qd2 0.975, 0.959 Jafari Ozumchelouei et al.53
Q d [cm3 min−1]
d n a [mm]
TBP–nitric acid [0.05 M] Pulsed disc and doughnut A: duty cycle (%) Dispersed phase hold up (φ) φ = 23 − 2.13A + 9.16B + 6.83C + 2.65D − 1.75AB + 6.15BC + 1.17CD + 0.52AD + 1.25BD + 0.33BCD n.d, 0.983 Sinha et al.54
B: Af [m s−1]
C: total throughput [m3 s−1]
D: O/A ratio
Toluene–water Oldshue–Rushton N [rpm] Sauter mean drop diameter (d32) d 32 = 11.062 − 0.045Qd − 0.046Qc − 0.072N + 0.0007QdQc − 2.1 × 10−5QdN + 7.1 × 10−6QcN + 0.0008Qd2 + 0.0005Qc2 + 0.0001N2 0.961, 0.926 Torkaman et al.55
Q c [m3 s−1]
Q d [m3 s−1]
Sulfate leach liquor – kerosene Horizontal pulsed column A f [cm s−1] Sauter mean drop diameter (d32) n.d. 0.999, 0.977 Khanramaki et al.41
Q c [L h−1] Efficiency (E)
Q d [L h−1]
a