Skip to main content
. 2022 Mar 30;30:e20210492. doi: 10.1590/1678-7757-2021-0492

Table 5. Correlation between clinical and CBCT findings (Pearson correlation coefficient).

CBCT variables and clinical parameters r p
Labial bone plate thickness (middle) vs probing depth (labial) -0.114 0.613
Lingual bone plate thickness (middle) vs probing depth (lingual) -0.201 0.37
Labial bone plate thickness (middle) vs clinical crown height -0.477 0.025*
Labial alveolar crest height vs clinical crown height 0.455 0.034*
Lingual alveolar crest height vs clinical crown height -0.081 0.721
Labial alveolar crest height vs probing depth (labial) -0.018 0.936
Lingual alveolar crest height vs probing depth (lingual) 0.251 0.26
Labial bone plate thickness (middle) vs recession -0.205 0.36
Labial bone plate thickness (middle) vs amount of keratinized mucosa 0.357 0.102
Labial bone plate thickness (middle) vs attachment level -0.646 0.001*
Labial alveolar crest height vs recession 0.141 0.532
Labial alveolar crest height vs amount of keratinized mucosa -0.443 0.039*
Labial alveolar crest height vs attachment level 0.597 0.003*