Skip to main content
. 2022 Mar 18;12(14):8559–8568. doi: 10.1039/d1ra09401g

Cone calorimetry results of POSS/D-bp/DGEBA hybrid compositesa,b,c,d.

Samples TTI (s) P-HRR (kW m−2) THR (MJ m−2) av-EHC (MJ kg−1) P-SPR (m2 s−1) Residues (wt%)
EP-1 53 939 202 31.6 0.35 13.5
EP-2 48 753 175 29.2 0.33 17.1
EP-3 53 767 134 29.0 0.30 17.3
EP-4 54 371 116 23.9 0.22 25.9
EP-5 49 651 130 23.6 0.29 18.1
EP-6 51 361 115 21.3 0.20 28.5
a

P-HRR: under the preset incident heat flux intensity, the maximum value of heat release rate per unit area after the material is ignited.

b

THR: the sum of the heat released by the material from ignition to flame extinction under the preset incident heat flow intensity.

c

EHC: the ratio of measured heat release rate to mass loss rate at a certain time reflects the combustion degree of volatile gas in gas phase flame.

d

P-SPR: the maximum value of specific extinction area (SEA) to mass loss rate (MLR).