TPA cross sections and γ at 650–1100 nm fitted from Z-scan experimental data. The error range of theoretical fitting is about 10%.
| Wavelength (nm) | Sample | β TPA (×10−14 m W−1) | σ TPA (GM) | γ (×10−28 m3 W−2) |
|---|---|---|---|---|
| 650 | INB3 | 10 | 154 | — |
| INT3 | 17 | 262 | 15 | |
| 700 | INB3 | 4.5 | 65 | — |
| INT3 | 10 | 143 | 6.0 | |
| 750 | INB3 | 0.5 | 7.0 | — |
| INT3 | 8.0 | 107 | 3.3 | |
| 800 | INB3 | 0.2 | 10 | 1.4 |
| INT3 | 3.5 | 38 | 1.3 | |
| 900 | INB3 | 6.0 | 67 | 2.0 |
| INT3 | 1.5 | 17 | 1.0 | |
| 950 | INB3 | 13 | 137 | 3.0 |
| INT3 | 2.0 | 21 | 0.5 | |
| 1030 | INB3 | 17 | 166 | 4.0 |
| INT3 | 8.5 | 83 | 0.5 | |
| 1100 | INB3 | 9.0 | 82 | 3.0 |
| INT3 | 5.0 | 46 | 0.3 |