Skip to main content
. 2022 Mar 23;12(15):9036–9043. doi: 10.1039/d2ra00402j

Catalytic activities over 1wt%Pt/CeO2 catalyst with/without the electric field (EF).

Temp./K CH4 conv./% CO2 conv./% H2/CO/— Power/W Energy efficiency/—
With EF 453 15.1 16.4 0.763 2.81 0.186
473 15.0 16.5 0.754 2.91 0.179
523 15.9 17.9 0.728 2.74 0.203
573 16.4 19.2 0.696 2.61 0.223
623 17.4 20.9 0.667 2.54 0.244
672 19.1 24.0 0.625 2.63 0.262
723 27.5 34.6 0.623 2.87 0.347
Without EF 472 0 0
523 0.00 0.01 0.00
573 0.03 0.07 0.00
623 0.15 0.42 0.00
673 0.66 1.60 0.135
723 2.21 4.75 0.237