Table 3.
Features | InterVA5 | InSilicoVA | SmartVA/Tariff |
---|---|---|---|
Computing platform compatibility | Windows MacOs Linux | Windows MacOs Linux | Windows only |
Number of indicators used by algorithm | 304 | 304 | 211 |
Exact implementation/replication in openVAa | Yes | Yes | No |
Implementation without training dataset | Yes | Yes | No |
Can produce instantaneous results for a single death | Yes | No | Yes |
Only significant symptoms used at individual level | No | No | Yes |
Accounts for absence of symptoms | No | Yes | No |
Accounts for missing symptoms | No | Yes | No |
Provides distribution of probabilities for each cause for a single death | Yes | Yes | No |
Provides measure of uncertainty for individual cause assignments | No | Yes | No |
Direct estimation of cause-specific mortality fractions | No | Yes | No |
Provides a distribution of probabilities for each CSMF | No | Yes | No |
Provides uncertainty measure for cause-specific mortality fractions | No | Yes | No |
aSource: Samuel J. Clark, openVA development team. www.openva.net.