Concentration of SARS-CoV-2 and NoV GII in WWTP influent measured with passive sampling and composite sampling.

SARS-CoV-2
NoV GII
Date of sampling Passive sampling
Composite sampling
Passive sampling
Composite sampling
(Log gc /100cm2) (Log gc /100 ml) (Log gc /100cm2) (Log gc /100 ml)
24-Nov-2020 1.7 4.1 1.2 3.2
25-Nov-2020 1.6 3.8 2.7 4.7
26-Nov-2020 1.8 4.4 2.8 4.6
27-Nov-2020 2.2 4.3 2.0 5.1
28-Nov-2020 2.2 4.0 <LD 5.2
29-Nov-2020 1.5 4.1 1.9 4.7
30-Nov-2020 1.4 4.1 <LD 4.6
1-Dec-2020 1.4 4.2 <LD 4.5
2-Dec-2020 1.6 3.8 2.3 4.5
3-Dec-2020 1.4 4.1 1.7 4.9
4-Dec-2020 2.4 3.9 ND 5.0
5-Dec-2020 2.8 4.0 ND 4.8
6-Dec-2020 1.8 3.9 ND 4.3
7-Dec-2020 2.4 3.7 ND 4.6
8-Dec-2020 2.4 3.9 ND 4.7
9-Dec-2020 2.3 4.2 ND 4.5
10-Dec-2020 2.6 4.1 1.9 4.1
11-Dec-2020 2.8 4.0 2.7 4.7
12-Dec-2020 3.0 4.0 1.8 4.1
13-Dec-2020 2.4 3.7 <LD 3.9
14-Dec-2020 3.2 4.1 1.4 4.0
mean ± SD 2.1 ± 0.5 4 ± 0.2 2.03 ± 0.5*** 4.51 ± 0.4
Frequency of detection (%) 100 100 76.2 100

Nylon membrane (100 cm2) were immersed in the influent of a WWTP during 24 h from the 24/11/2020 to 14/12/2020; composite sampling: 24 h composite sample of raw wastewater. LD: limit of detection; ND: not determined. ANOVA was followed by Tukey's multiple comparisons test: ***p < 0.001.